AIR SPARGING - LOW PRESSURES

A. Basic Air Sparging Packages
Standard Features:
- PD Blower or Rotary Vane Pump
- TEFC or EXP motor
- Steel base with forklift tubes
- Discharge pressure and temperature gauge
- inlet filter
- Premium combination chamber-absorptive type discharge silencer
*Core air sparging system based on process pipe size Sparge System
PART MODEL DIA. DESCRIPTION
NO.   (in)  
       
AIP1   1 Basic Air Sparging Package
AIP2   2  
AIP3   2.5  
AIP4   3  
AIP5   4  
B. Blower / Compressor Selection
Positive Displacement Blowers
PART MODEL DIA. DESCRIPTION
NO.   INL. (Flow/ Horsepower / Maximum Pressure)
      Blower Selection (for PD Air Sparge Systems)
PD1 2LVP 2-S 56-162 SCFM / 1-7.5 HP / 7 psig
PD2 3LVP 2.5-S 120-341 SCFM / 1-15 HP / 7 psig
PD3 4LVP 3-S 213-566 SCFM / 3-25 HP / 7psig
PD4 5LVP 4-S 387-953 SCFM / 5-40 HP / 7 psig
PD5 6LVP 6-S 614-1614 SCFM / 7.5-60 HP / 7 psig
PD6 2MVP 1-S 30-60 SCFM / 1-5 HP / 12 psig
PD7 3MVP 2-S 70-150 SCFM / 3-10 HP / 12 psig
PD8 4MVP 2.5-S 140-350 SCFM / 5-20 HP / 12 psig
PD9 5MVP 4-S 210-540 SCFM / 7.5-25 HP / 12 psig
PD10 6MVP 5-S 270-815 SCFM / 10-40 HP / 12 psig
PD11 7MVP 6-F 600-1383 SCFM / 15-60 HP / 12 psig
PD12 3HVP 1.25-S 40-138 SCFM / 3-7.5 HP / 15 psig
PD13 4HVP 1.5-S 72-218 SCFM / 3-10 HP / 15 psig
PD14 5HVP 2.5-S 134-359 SCFM / 5-20 HP / 15 psig
PD15 6HVP 3-S 152-477 SCFM / 7.5-25 HP / 15 psig
PD16 7HVP 4-S 278-682 SCFM / 10-40 HP / 15 psig
PD17 8HVP 4-S 40-138 SCFM / 3-7.5 HP / 15 psig
11. AIR SPARGING - LOW PRESSURES (cont'd)
Rotary Vane Compressors - Low Pressure (Gast, Rietschle, Becker, or equal)
PART MODEL DIA. DESCRIPTION
NO.   INL.
(Manufacturer / Flow / Max. Pressure)
    Rotary Vane Pump Selection
RVP1 2080 3/4 Gast / 18 SCFM / 15 psig
RVP2 3080 3/4 Gast / 26 SCFM / 15 psig
RVP3 6066 1 Gast / 42 SCFM / 20 psig
RVP4 MM1104 0.75 Busch 1104 42cfm/23.5psig
RVP5 DTA60 1 Busch 1144 58cfm/16 psig
RVP6 DTA80 1 Busch 1102 86cfm/23.5 psig
RVP7 DTA100 1.25 Busch 1122 100cfm/29.5 psig
RVP8 DTA140 1.25
Busch 1322 218cfm/31 psig
RVP9 DLR400 4 Busch 1502 43cfm/29.2 psig
RVP10 KDT3.60 1 Becker / 29 SCFM / 22 psig
RVP11 KDT3.80 1 Becker / 38 SCFM / 22 psig
RVP12 KDT3.100 1.5 Becker / 47 SCFM / 22 psig
RVP13 KDT3.140 1.5 Becker / 80 SCFM / 22 psig
RVP14 DTLF250 2.5 Becker / 160 SCFM / 25 psig
RVP15 DTLF500 4 Becker / 325 SCFM / 25 psig
      Motor Selection ( for PD SVE Systems)
Standard Motors 3 phase 1800 RPM. TEFC are assumed Class 1 Div 2
PART MOTOR HP DESCRIPTION
NO. TYPE    
PDM0.2 TEFC 2 PD Blower Motor 145T
PDM 0.4 XP 2  
PDM 0.6 XP 2  
PDM1 TEFC 3 PD Blower Motor 182T
PDM2 TEFC 3 PD Blower Motor 182T
PDM3 EXP 3  
PDM4 EXP 3  
PDM5 TEFC 5 PD Blower Motor 184T
PDM6 EXP    
PDM7 TEFC 5 PD Blower Motor 184T
PDM8 EXP    
PDM9 TEFC 7.5 PD Blower Motor 213T
PDM10 EXP    
PDM11 TEFC 10 PD Blower Motor 215T
PDM12 EXP    
PDM13 TEFC 15 PD Blower Motor 254T
PDM14 EXP    
PDM15 TEFC 20 PD Blower Motor 256T
PDM16 EXP    
PDM17 TEFC 25 PD Blower Motor 284T
PDM18 EXP    
PDM19 TEFC 30 PD Blower Motor 286T
PDM20 EXP    
PDM21 TEFC 40 PD Blower Motor 324T
PDM22 EXP    
PDM23 TEFC 50 PD Blower Motor 326T
PDM24 EXP    
 
PART MODEL HP DESCRIPTION
NO.     (Voltage)
C.     Variable Frequency Drive (for RPM Control)GPD 505/P5  
VFD1 FW-174457 2 200-230 VAC Variable Frequency Drive
VFD2 FW-174458 3  
VFD3 FW-174446 5  
VFD4 FW-174438 7.5  
VFD5 FW-174439 10  
VFD6 FW-174557 15  
VFD7 FW-174560 20  
VFD8 FW-174569 25  
VFD9 FW-174571 30  
VFD10 FW-174567 40 460-480 VAC Variable Frequency Drive
VFD11 FW-174593 50  
Home